Search results for "Internal jugular vein"
showing 10 items of 23 documents
Blood flow in the internal jugular veins during the spaceflight - Is it actually bidirectional?
2020
Recently intriguing results of the research performed on astronauts of the International Space Station have been published. Unexpectedly, in some crew members a stagnant and bidirectional flow in the internal jugular vein was found, and in one of the astronauts this vein seemed to be totally thrombosed. If it actually were the case that in the settings of weightlessness there is a substantial risk of jugular vein thrombosis, any long-term human space missions would be extremely dangerous. Yet, we interpret these findings differently. In our opinion, what has been explained as bidirectional flow, actually represented the flow separation, and what has been described as occluded vein was rathe…
Collapsibility of the internal jugular veins in the lateral decubitus body position: A potential protective role of the cerebral venous outflow again…
2019
Recent research has revealed that patients with neurodegenerative disease sleep longer in the supine position, while healthy controls prefer sleeping in the lateral decubitus position. Thus, sleeping in the lateral position seems to be protective against neurodegeneration. It has also been suggested that a protective role of this body position could be associated with better cerebral venous drainage in this body position, which results in more active glymphatic system of the brain (the system responsible for clearance of the cerebral tissue from waste products, e.g. amyloid-β). Since no published evidence exists regarding venous outflow from the cranial cavity in the lateral decubitus posit…
Analysis of Internal Jugular Vein Insufficiency—A Comparison of Two Ultrasound Methods
2006
Abstract Jugular venous valve insufficiency is a contributing factor to different pathologic conditions. For assessment of insufficiency, two ultrasound techniques have been developed, that are based on very different methodology (direct Doppler assessment versus air contrast ultrasound venography [ACUV]). This study was conducted to compare these two methods to improve comparability of existing studies and diagnostic accuracy in future studies. The function of 40 valves was determined in 20 individuals during a Valsalva maneuver. For direct Doppler assessment, valvular competence was assessed on basis of Doppler recordings, following recently established criteria. Valvular insufficiency in…
The Prevalence of Chronic Cerebrospinal Venous Insufficiency in Meniere Disease: 24-Month Follow-up after Angioplasty
2016
Abstract Purpose To evaluate relationship between Meniere disease (MD) and chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound, magnetic resonance (MR) imaging, and venography and to evaluate the effectiveness of angioplasty of the internal jugular vein (IJV) and azygos vein (AV) in reducing symptoms of MD. Materials and Methods Patients with a confirmed diagnosis of MD unresponsive to standard treatment underwent duplex ultrasound and MR imaging to diagnose CCSVI. Healthy volunteers were also studied to evaluate CCSVI in asymptomatic subjects. Patients with CCSVI and MD underwent venography and percutaneous transluminal angioplasty (PTA) of IJV and AV. Results There were 18…
Lemierre Syndrome: Clinical Update and Protocol for a Systematic Review and Individual Patient Data Meta-analysis.
2018
Lemierre syndrome usually affects otherwise healthy adolescents or young adults and occurs at an overall rate of 1 to 10 cases per million person-years with an estimated fatality rate of 4 to 9%. Diagnostic criteria remain debated and include acute neck/head bacterial infection (often tonsillitis caused by anaerobes at high potential for sepsis and vascular invasion, notably Fusobacterium necrophorum) complicated by local vein thrombosis, usually involving the internal jugular vein, and systemic septic embolism. Medical treatment is based on antibiotic therapy with anaerobic coverage, anticoagulant drugs and supportive care in case of sepsis. Surgical procedures can be required, including d…
Involvement of Jugular Valve Insufficiency in Cerebral Venous Air Embolism
2007
Background. Cerebral venous air entrapment is a rare finding on cranial computed tomography (CT) scan. Peripheral air embolism is discussed as a potential cause. However, the mechanism of retrograde passage through internal jugular valves and veins is unclear. Case Report. The case of a patient is reported, who had air entrapment in the left cavernous sinus. Prior to CT scanning, a peripheral intravenous line had been placed. Ultrasound revealed excessive insufficiency of the left internal jugular valve. To further study the mechanism of embolism, an echo contrast agent was injected into the cubital vein. A Valsalva maneuver resulted in retrograde transition of microbubbles across the insuf…
Transcervical approach for carotid artery stenting with transitory reversal flow: Case report
2021
Introduction Carotid artery stenting (CAS) has been indicated as an alternative to carotid endarterectomy in high risk patients. Sometimes, an aortic arch can be anatomically unfavourable for CAS. Herein we report our experience in a case of CAS with transcervical approach. Presentation of case A 77-year-old male was referred to our hospital for severe subtotal occlusion of the left internal carotid artery. He had a past medical history of radiation to the head and neck for laryngeal cancer. Previous CT-angiography had shown a type III aortic with bovine arch. CAS via transcervical approach was performed with transitory reversal flow during the placement of RX Spider Filter 6 Fr (Medtronic,…
Ultrasonography for evaluation of the carotid artery in head and neck cancer.
1994
The dynamic relationship of lymph node metastases to surrounding vascular structures in the neck is important for preoperative patient assessment. When carotid artery involvement is suspected, this relationship often determines whether or not to operate. In the case of adhesive neck metastases along the internal jugular vein, it becomes possible to predict preoperatively if the integrity of this vein may be preserved. Ultrasonography has the ability to differentiate subtle from gross adherence, or simple compression from vascular invasion. This is done by manually palpating the tumor mass and asking the patient to perform various maneuvers while observing on a monitor the relationship of th…
Results of Numerical Modeling of Blood Flow in the Internal Jugular Vein Exhibiting Different Types of Strictures
2022
The clinical relevance of nozzle-like strictures in upper parts of the internal jugular veins remains unclear. This study was aimed at understanding flow disturbances caused by such stenoses. Computational fluid dynamics software, COMSOL Multiphysics, was used. Two-dimensional computational domain involved stenosis at the beginning of modeled veins, and a flexible valve downstream. The material of the venous valve was considered to be hyperelastic. In the vein models with symmetric 2-leaflets valve without upstream stenosis or with minor 30% stenosis, the flow was undisturbed. In the case of major 60% and 75% upstream stenosis, centerline velocity was positioned asymmetrically, and areas of…
Renal Transplantation by Automatic Anastomotic Device in a Porcine Model
2015
Automatic vascular staplers for vascular anastomoses in kidney transplantation may dramatically reduce the operative time and, in particular, warm ischemia time, thus increasing the outcome of transplantation. Ten pigs underwent kidney auto-transplantation by automatic anastomotic device. Kidneys were collected by laparotomy with selective ligations at the renal hilum and perfused with cold storage solution. To overcome the shortage in length of renal hilum, a tract of the internal jugular vein was harvested to increase the length of the vessels. The anastomoses were totally performed by the use of the anastomotic device. On 10 kidney transplants, nine were successful and no complications o…